Baltimore Aircoil Company (BAC) is the world’s largest manufacturer of cooling towers. With over 75 years of experience and over 100 patents in the field, BAC offers reliable and efficient cooling technologies for industrial, HVAC and refrigeration processes.
Open cooling towers discharge heat from water-cooled systems into the atmosphere. The hot process water is distributed over a fill pack (heat transfer media) to interface with air blown by a fan through the cooling tower. During this evaporative cooling, a small part of the water evaporates while cooling the remaining process water.
Very efficient cooling
Low process temperatures
Small footprint design
Patented Baltibond hybrid coating
Low energy consumption
Eurovent certifications
Overview
Since 1978, thousands globally installed, proving the VT0/1-previously called VXT- cooling tower reliability.
Fans, motor and drive system (V-belt) are located in the dry air, preventing moisture and condensation. No external moving parts, helping it withstand the toughest weather.
The thermal performance of VT0/1 cooling towers is tested and certified by Eurovent.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
VT0/1 units include quiet internal centrifugal fans for minimal surrounding noise.
Single-side air inlet, and a quieter tower rear for more noise-sensitive areas.
Cut operation noise still further with factory-designed and tested sound attenuators or silencers.
Compact design for confined spaces.
Single-side air inlet lets you install next to solid walls.
Units housable indoors thanks to centrifugal fans allowing intake or discharge ductwork.
VT0/1 towers are factory-assembled. We ship larger models in 2 sections to reduce the size and weight of the heaviest section for easy on-site assembly with smaller cranes.
VT0/1 offers high capacity and minimal operating weight. Save on steel supports, both underneath the equipment and in the building itself for rooftop installations.
VT0/1 towers can be container-shipped (in 12’ containers). Fan enclosures shippable loose in the tower bottom section for easy on-site assembly.
Easy access to all the mechanicals, including fan shaft bearings.
BACount individual bundled fill sheets for easy and complete inspection or cleaning preventing full replacement of fill bundles.
Principle of Operation
Warm process water (1) from the heat source enters the spray system (2) at the top of the cooling tower where it is distributed over the fill or heat transfer media (3). At the same time, the centrifugal fan (4) of the air movement system, located at the bottom of the cooling tower, blows ambient air (5) upwards through the tower. While the warm process water contacts the cold air the latter heats up and part of the process water is evaporated resulting in an optimal heat transfer. The tower sump (6) or basin collects the cooled water (7) after which it returns to the heat source of the process. The warm saturated air (8) leaves the tower through the drift eliminators (9), which remove water droplets from the air.
Overview
Very low height: fits perfectly on roof tops or tight enclosures.
VTL-E towers are factory-assembled. We ship in one piece for easy on-site lifting and installation.
VTL-E offers high capacity and minimum operating weight. Save on steel supports, both underneath the equipment and in the building itself for rooftop installations.
Single-side air inlet lets you install next to solid walls.
Units housable indoors thanks to centrifugal fans allowing intake or discharge ductwork.
VTL-E units include quiet internal centrifugal fans for minimal surrounding noise.
Single-side air inlet, and a quieter tower rear for more noise-sensitive areas.
Cut operation noise still further with factory-designed and tested sound attenuators or silencers.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
Optional Baltiguard Drive System for energy savings and less noise during low load (night). A perfect stand-by system in case of motor failure.
The thermal performance of VTL-E is Eurovent certified.
Easy access to all the mechanicals, including fan shaft bearings.
BACount individual bundled fill sheets for easy and complete inspection or cleaning preventing full replacement of fill bundles.
Principle of Operation
Warm process water (1) from the heat source enters the spray system (2) at the top of the cooling tower where it is distributed over the fill or heat transfer media (3). At the same time the centrifugal fan (4) blows ambient air (5) upwards through the tower. While the warm process water contacts the cold air the latter heats up and part of the process water is evaporated which removes the heat from the remaining water. The tower sump (6) or basin collects the cooled water (7) after which it returns to the heat source of the process. The warm saturated air (8) leaves the tower through the drift eliminators (9), which remove water droplets from the air.
Overview
A choice of various fan types such as low noise axial fans and Wisper Quiet fans for minimal surrounding noise.
BACross fill smoothly guides the water all the way into the basin without water splash noise.
Single-side air inlet, and a quieter tower rear for more noise-sensitive areas.
Try our XES1500E line with smaller motors for extremely low noise levels.
Factory designed, tested and rated sound attenuation is available on air inlet to cut operation noise even further.
Evaporative cooling for system-wide energy saving at lower operating temperatures.
Axial fan uses half the energy of similar centrifugal fan units.
Save pump kW! Less pump head for this gravity water distribution system. In periods of reduced load, weir dams close off partly the hot water basin saving pump energy.
BACross fill – factory-configured for maximum water/air contact and low air pressure drop for optimal cooling tower efficiency with limited energy consumption.
High efficiency fan motors
Multiple fan motor system covers independent fan motor and drive assembly per fan. In case of fan failure, the other fan(s) can still operate.
XES1500E line with smaller motors to reduce electricity consumption for the same cooling capacity.
Unrivalled safe and comfortable access. Inspect and maintain the tower while standing and without crawling.
The S1500E has a spacious plenum (internal area) and easy inspection/maintenance access.
Access via large hinged door. With optional internal walkway: no basin draining needed for unit interior or fill pack inspection.
Inspection of water distribution system (hot water basin and nozzles) possible outside the unit, during operation.
Optional distribution basin covers prevent debris collecting in the unit.
You can inspect and clean easily the core of the BACross fill sheet by sheet without dismantling. BACross design reduces fouling. Optional telescopic fill supports for easy replacement of the sheets.
The fill includes integrated drift eliminators tested and certified by Eurovent.
Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
Fans are easily accessible from the in- and outside
Optional clean out port helps remove silt and sludge from the cooling tower basin.
Removable suction strainer anti-vortex hood.
Optional sump sweeper piping prevents sediment collecting in the cold water basin.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
Optional motor removal davit for easy motor replacement.
Proper hygiene inspection without unit shut-down.
Easy-clean and easy-inspect S1500E towers reduce hygiene risks from bacteria (eg Legionella) or biofilm inside.
Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
BACross fill for reduced fouling and easy sheet by sheet cleaning without dismantling.
The fill includes integrated drift eliminators tested certified by Eurovent.
Combined inlet shields block sunlight to prevent biological growth in the tower, filter the air and stop water splashing outside.
Optional distribution basin covers prevent debris collecting in the unit.
Optional clean out port helps remove silt and sludge from the cooling tower basin.
Optional sump sweeper piping prevents sediment collecting in the cold water basin.
Single side air inlet and discharge, fits in most enclosures.
S1500E are ideal replacement units. Small fan motors and low spray pressure allow re-use of existing electrical cabinet.
S1500E cooling towers are factory-built and shipped in 1 or 2 sections to reduce the overall size and weight, allowing easy on-site section assembly with smaller crane.
Optimal unit condition thanks to inspection during operation.
Proven freeze free winter operation.
The thermal performance of S1500E is tested and certified by Eurovent.
Multiple fan motor system covers independent fan motor and drive assembly per fan. In case of fan failure, the other fan(s) can still operate.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
Principle of Operation
Overview
A choice of various fan types such as low noise axial fans and Whisper Quiet fans for minimal surrounding noise
BACross fill smoothly guides the water all the way into the basin without water splash noise.
Try our XES3000E line with smaller motors for extremely low noise levels.
Factory designed, tested and rated sound attenuation is available on air inlet and discharge to cut operation noise even further.
Evaporative cooling for system-wide energy saving at lower operating temperatures.
Axial fan uses half the energy of similar centrifugal fan units.
Save pump kW! Less pump head for this gravity water distribution system. In periods of reduced load, weir dams close off partly the hot water basin saving pump energy.
BACross fill – factory-configured for maximum water/air contact and low air pressure drop for optimal cooling tower efficiency with limited energy consumption.
High efficiency fan motors
XES3000E line with smaller motors to reduce electricity consumption for the same cooling capacity.
The S3000E has a spacious plenum (internal area) and easy access to inspect and maintain safely the unit interior components. Unrivalled comfort, while standing inside.
Upgrade the unit interior with ladder and platform for quick and safe access to all unit components.
Access via large hinged door to optional internal walkway: no basin draining needed for unit interior or fill pack inspection.
You can inspect and clean easily the core of the BACross fill sheet by sheet without dismantling. BACross design reduces fouling. Optional telescopic supports for easy replacement of the sheets.
The fill includes integrated drift eliminators tested and certified by Eurovent.
Inspection of water distribution system (hot water basin and nozzles) possible outside the unit, during operation.
Optional distribution basin covers prevent debris collecting in the unit.
Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
Fans are easily accessible from the in- and outside
Optional clean out port helps remove silt and sludge from the cooling tower basin.
Removable suction strainer anti-vortex hood.
Optional sump sweeper piping prevents sediment collecting in the cold water basin.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
Easy-clean and easy-inspect S3000E towers reduce hygiene risks from bacteria (eg Legionella) or biofilm inside.
Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
BACross fill for reduced fouling and easy sheet by sheet cleaning without dismantling.
The fill includes integrated drift eliminators tested and certified by Eurovent.
Combined inlet shields block sunlight to prevent biological growth in the tower, filter the air and stop water splashing outside.
Optional distribution basin covers prevent debris collecting in the unit.
Optional clean out port helps remove silt and sludge from the cooling tower basin.
Optional sump sweeper piping prevents sediment collecting in the cold water basin.
Top rated thermal performance – meets any flow and temperature needs.
The thermal performance of S3000E cooling towers is tested and certified by Eurovent.
Patented BACross sheet fill with maximum air and water contact gives unbeatable heat transfer performance.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating and FRP casing panels for guaranteed long service life.
Optional gear-drive system for more efficiency and less maintenance.
Principle of Operation
Overview
Evaporative cooling for system-wide energy saving at lower operating temperatures.
Axial fan uses half the energy of similar centrifugal fan units.
The thermal performance of the PTE is tested and certified by Eurovent.
Factory tested high efficiency Versapak fill with maximum air/water contact at low air pressure drops
High efficiency fan motors
PTE features low noise axial fans. To reduce noise even further, choose for Whisper Quiet fans.
Factory designed, tested and rated sound attenuation is available on the discharge for further noise reduction.
Water silencers achieve noise levels close to those of crossflow towers. Water silencers come always with Whisper Quiet fans.
The PTE open cooling tower is easier to maintain than other induced draft counterflow cooling towers.
BranchLok water distribution – each branch removable for easy cleaning.
Combined inlet shields for easy no-tool removal.
Fill bundle modules, with optional handles and removable side panels for better and easier fill inspection and replacement.
Motor adjusters: externally accessible and locking wrench for easy motor alignment and belt tensioning.
Full cold water basin access when removing the combined inlet shields.
Fans easy accessible via sliding access door.
Optional clean out port helps remove silt and sludge from the cooling tower basin.
Removable suction strainer anti-vortex hood.
The leak-free InterLok system means swift PTE tower on-site assembly. Install the basin on the upper section with no sealer tape in between!
Compact PTE footprint – perfect for confined spaces.
Container shipment often possible!
Easy-clean and easy-inspect PTE towers reduce hygiene risks from bacteria (eg Legionella) or biofilm inside.
Self-cleaning cold water basin and fill above sloped basin to flush out dirt and debris.
Factory tested and Eurovent certified high efficient drift eliminators.
Combined inlet shields block sunlight to prevent biological growth in the tower, filter the air and stop water splashing outside.
Optional sump sweeper piping prevents sediment collecting in the cold water basin.
Principle of Operation
Overview
FXT towers are factory-assembled for easy on-site assembly with smaller cranes.
Evaporative cooling for system-wide energy saving at lower operating temperatures.
Axial fan uses half the energy of similar centrifugal fan units.
BACross fill – factory-configured for maximum water/air contact and low air pressure drop for optimal cooling tower efficiency with limited energy consumption.
Save pump kW! Less pump head for this gravity water distribution system.
You can inspect the water distribution system (hot water basin and nozzles) outside the unit, during operation.
Easy access to fill and drift eliminators from outside.
Easy removable air inlet screens for access to fans, bearings, motor and drive.
Various corrosion-resistant materials, including the unique Baltibond hybrid coating for guaranteed long service life.
Principle of Operation
Technical Concept and 3D Design
Equipment distribution and implementation
Fitting
Turnkey projects
Remote automation and monitoring systems
Rehabilitation and upgrades for all types of cooling towers
Service and after-sales service