+4 031 803 48 86

0,00 lei

You have no items in your basket.

Open circuit cooling tower BAC - VT0-1

Product code: VT0-1
0,00 lei VAT included 0,00 lei Excl. VAT

Open circuit cooling towers, VT0-1 range are forced draft towers with countercurrent flows and centrifugal fans.

Key benefits

  • RELIABLE
  • Silent
  • Compact

Typical applications

  • Small and medium industrial and HVAC applications
  • Placement in narrow spaces and installations that require only one air intake
  • Indoor installation
  • Sound sensitive installations
  • High temperature industrial applications

Description

General presentation

Reliable operation guaranteed

Since 1978, thousands of such models have been installed globally, proving the reliability of the VT0/1 model, formerly known as the VXT.

The fans, motor and drive system are located in the dry air stream, preventing condensation and moisture. There are no external moving parts and the system is able to withstand harsh environmental conditions.

The thermal performance of VT0/1 cooling towers is tested and certified by Eurovent.

Various corrosion-resistant materials are available, including Baltibond, patented hybrid coating, to guarantee a long life.

Ideal for silent operation

VT0/1 cooling towers include silent centrifugal fans placed inside to ensure low noise around the unit.

The air intake is carried out on one side, the cooling towers can be located in areas more sensitive to noise.

Noise can be further reduced during operation with noise attenuators designed and tested in the factory.

Compact 

  • Compact design, cooling towers can be placed in tight spaces
  • Single-sided suction allows towers to be installed near building walls
  • These cooling towers can be placed indoors thanks to centrifugal fans

Low transport, assembly and installation costs

VT0/1 cooling towers are factory assembled. Larger cooling tower models are delivered in 2 sections for easier on-site assembly with smaller cranes.

VT0/1 towers can operate at high capacity and minimum operating weight. Steel supports, required to be located both under the equipment and in the building when the cooling towers are installed on the roof, can be saved.

VT0/1 towers can be shipped in containers. Fan housings can be shipped with the lower tower section for easy on-site assembly.

Easy maintenance

Easy access to all mechanical components, including fan shaft bearings

The individual filler packets BACount allow complete and easy inspection and cleaning, preventing complete replacement of stuffing packs.

Operating principle

Hot process water (1) enters the spray system (2) through the top of the cooling tower where it is distributed over the packing (3). At the same time, the centrifugal fan (4), located at the bottom of the cooling tower, blows ambient air (5) up through the tower. As the hot process water comes into contact with the cold air, the latter heats up and part of the process water is evaporated, resulting in optimal heat transfer. Cooled water (6) is collected in the tower basin (7) and sent to the process heat source. The warm saturated air (8) leaves the cooling tower through the droplet separators (9).

Read more

We also recommend you